Hermes-agent
This commit is contained in:
@@ -0,0 +1,395 @@
|
||||
"""Harness: `docker run <image> gateway run` redirects to supervised mode.
|
||||
|
||||
Before the s6 migration, ``docker run nousresearch/hermes-agent gateway
|
||||
run`` was the standard pattern — the gateway ran as the container's
|
||||
main process, container exit code matched gateway exit code, no
|
||||
supervision. With s6 as PID 1, the same invocation now auto-redirects
|
||||
to the supervised path (`gateway start`) so users get auto-restart on
|
||||
crash and a supervised dashboard alongside (when ``HERMES_DASHBOARD=1``).
|
||||
|
||||
These tests verify the three load-bearing properties of that redirect:
|
||||
|
||||
1. The default invocation **does** redirect (container stays up via
|
||||
``sleep infinity`` while s6 supervises ``gateway-default``).
|
||||
2. ``--no-supervise`` / ``HERMES_GATEWAY_NO_SUPERVISE=1`` opts out.
|
||||
3. The supervised process itself does NOT recurse — the
|
||||
``HERMES_S6_SUPERVISED_CHILD`` sentinel breaks the loop.
|
||||
|
||||
Every ``docker exec`` runs as ``hermes`` per the conftest module
|
||||
docstring; see ``tests/docker/conftest.py`` for rationale.
|
||||
"""
|
||||
from __future__ import annotations
|
||||
|
||||
import subprocess
|
||||
import time
|
||||
|
||||
from tests.docker.conftest import docker_exec_sh
|
||||
|
||||
|
||||
def _sh(container: str, command: str, timeout: int = 30):
|
||||
return docker_exec_sh(container, command, timeout=timeout)
|
||||
|
||||
|
||||
def _svstat(container: str, slot: str = "gateway-default") -> str:
|
||||
r = _sh(container, f"/command/s6-svstat /run/service/{slot}")
|
||||
return r.stdout if r.returncode == 0 else ""
|
||||
|
||||
|
||||
def _svstat_wants_up(container: str, slot: str = "gateway-default") -> bool:
|
||||
"""See test_profile_gateway._svstat_wants_up for the format rules."""
|
||||
state = _svstat(container, slot)
|
||||
if not state:
|
||||
return False
|
||||
head = state.split()[0] if state.split() else ""
|
||||
if head == "up":
|
||||
return "want down" not in state
|
||||
return "want up" in state
|
||||
|
||||
|
||||
def test_gateway_run_redirects_to_supervised(
|
||||
built_image: str, container_name: str,
|
||||
) -> None:
|
||||
"""``docker run <image> gateway run`` (the historical invocation)
|
||||
should now register and start the ``gateway-default`` s6 slot.
|
||||
|
||||
The CMD process itself shouldn't be the gateway — it should be
|
||||
blocked on ``sleep infinity``, leaving s6 to supervise the actual
|
||||
gateway process. We verify by:
|
||||
|
||||
* Confirming the CMD process is sleeping (not python/gateway).
|
||||
* Confirming ``s6-svstat gateway-default`` reports want-up.
|
||||
"""
|
||||
# Start the container detached using the historical gateway-run
|
||||
# pattern. The redirect should fire and the container should NOT
|
||||
# exit immediately (which is what would happen pre-this-PR on the
|
||||
# s6 image — the foreground gateway would crash without config,
|
||||
# the CMD would exit, /init would shut down).
|
||||
subprocess.run(
|
||||
["docker", "run", "-d", "--name", container_name, built_image,
|
||||
"gateway", "run"],
|
||||
check=True, capture_output=True, timeout=30,
|
||||
)
|
||||
|
||||
# Give /init time to run cont-init.d, the wrapper time to dispatch
|
||||
# the redirect, and s6-supervise time to spin up the slot.
|
||||
time.sleep(5)
|
||||
|
||||
# Container should still be running. If the redirect didn't fire,
|
||||
# the foreground gateway would have crashed and the container
|
||||
# would be in `Exited` state by now.
|
||||
r = subprocess.run(
|
||||
["docker", "inspect", "-f", "{{.State.Status}}", container_name],
|
||||
capture_output=True, text=True, timeout=10,
|
||||
)
|
||||
assert r.returncode == 0 and r.stdout.strip() == "running", (
|
||||
f"container exited prematurely: {r.stdout!r}; "
|
||||
f"docker logs:\n{subprocess.run(['docker', 'logs', container_name], capture_output=True, text=True).stdout}"
|
||||
)
|
||||
|
||||
# s6's intent for the default-profile gateway slot should be up.
|
||||
# Same accept-either rule as test_profile_gateway: the supervised
|
||||
# gateway may or may not be currently up depending on whether the
|
||||
# harness profile has a configured model, but the want-intent
|
||||
# contract holds either way.
|
||||
assert _svstat_wants_up(container_name), (
|
||||
f"gateway-default slot want-state not up: {_svstat(container_name)!r}"
|
||||
)
|
||||
|
||||
# The CMD process (PID under /init that the wrapper exec'd into)
|
||||
# should be sleeping, not the gateway. We grep `ps` for the
|
||||
# `sleep infinity` heartbeat.
|
||||
r = _sh(container_name, "ps -eo pid,cmd | grep -v grep | grep 'sleep infinity'")
|
||||
assert r.returncode == 0 and "sleep infinity" in r.stdout, (
|
||||
f"expected `sleep infinity` heartbeat process; got ps:\n{r.stdout}\n"
|
||||
f"stderr: {r.stderr}"
|
||||
)
|
||||
|
||||
# And the loud breadcrumb should be in `docker logs` so users see
|
||||
# the upgrade explanation.
|
||||
r = subprocess.run(
|
||||
["docker", "logs", container_name],
|
||||
capture_output=True, text=True, timeout=10,
|
||||
)
|
||||
logs = r.stdout + r.stderr
|
||||
assert "s6 supervision" in logs, (
|
||||
f"expected loud breadcrumb in docker logs; got:\n{logs}"
|
||||
)
|
||||
assert "--no-supervise" in logs, (
|
||||
f"breadcrumb missing opt-out hint; got:\n{logs}"
|
||||
)
|
||||
|
||||
|
||||
def test_gateway_run_no_supervise_flag_preserves_legacy_behavior(
|
||||
built_image: str, container_name: str,
|
||||
) -> None:
|
||||
"""``docker run <image> gateway run --no-supervise`` opts out of
|
||||
the redirect and runs the gateway as the foreground CMD process
|
||||
(pre-s6 semantics).
|
||||
|
||||
With the redirect in place, the container's CMD process would be
|
||||
``sleep infinity`` and the supervised gateway would be a separate
|
||||
process under ``s6-supervise gateway-default``. WITHOUT the
|
||||
redirect (opt-out path), there's no supervised gateway slot at
|
||||
all — the gateway IS the CMD process.
|
||||
|
||||
Three positive assertions confirm we took the pre-s6 path:
|
||||
|
||||
* The CMD process is a python ``hermes gateway run`` invocation
|
||||
(not ``sleep infinity``).
|
||||
* The ``gateway-default`` s6 service slot is NOT created.
|
||||
* No supervision-redirect breadcrumb appears in docker logs.
|
||||
"""
|
||||
subprocess.run(
|
||||
["docker", "run", "-d", "--name", container_name, built_image,
|
||||
"gateway", "run", "--no-supervise"],
|
||||
check=True, capture_output=True, timeout=30,
|
||||
)
|
||||
# Give startup time. The unconfigured-profile case used to fail
|
||||
# fast; with a config bind-mounted profile (and a real volume on
|
||||
# most realistic deployments) the gateway just runs.
|
||||
time.sleep(6)
|
||||
|
||||
# Container should still be running OR have exited cleanly with
|
||||
# the gateway's status code. Either is correct for pre-s6
|
||||
# semantics — what's NOT correct is the supervised behavior
|
||||
# (sleep infinity heartbeat + supervised gateway slot).
|
||||
inspect = subprocess.run(
|
||||
["docker", "inspect", "-f", "{{.State.Status}}", container_name],
|
||||
capture_output=True, text=True, timeout=10,
|
||||
)
|
||||
status = inspect.stdout.strip()
|
||||
|
||||
# No redirect breadcrumb anywhere.
|
||||
logs = subprocess.run(
|
||||
["docker", "logs", container_name],
|
||||
capture_output=True, text=True, timeout=10,
|
||||
).stdout + subprocess.run(
|
||||
["docker", "logs", container_name],
|
||||
capture_output=True, text=True, timeout=10,
|
||||
).stderr
|
||||
assert "s6 supervision" not in logs, (
|
||||
f"--no-supervise should have skipped the redirect; "
|
||||
f"breadcrumb in logs:\n{logs}"
|
||||
)
|
||||
|
||||
if status == "running":
|
||||
# Gateway running in foreground — the CMD process should be
|
||||
# the gateway itself, NOT a sleep-infinity heartbeat.
|
||||
r = _sh(
|
||||
container_name,
|
||||
"ps -eo pid,ppid,cmd | grep -v grep | awk '/main-wrapper.sh|rc.init top/ { wrapper_pid=$1 } "
|
||||
"$3==\"sleep\" && $4==\"infinity\" && $2==wrapper_pid { c++ } END { print c+0 }'",
|
||||
)
|
||||
assert r.returncode == 0
|
||||
redirected_sleeps = int(r.stdout.strip() or 0)
|
||||
assert redirected_sleeps == 0, (
|
||||
f"--no-supervise: expected NO `sleep infinity` parented to "
|
||||
f"the CMD wrapper (foreground gateway should be the CMD), "
|
||||
f"found {redirected_sleeps}. "
|
||||
f"ps:\n{_sh(container_name, 'ps -eo pid,ppid,cmd').stdout}"
|
||||
)
|
||||
|
||||
# The gateway-default s6 slot exists (the cont-init.d
|
||||
# reconciler creates it on every boot regardless of opt-out)
|
||||
# but should NOT have its want-state set to "up" — the
|
||||
# opt-out path doesn't dispatch `start` to s6.
|
||||
assert not _svstat_wants_up(container_name, "gateway-default"), (
|
||||
"--no-supervise: gateway-default slot has want-state up, "
|
||||
"implying the redirect dispatched `start` despite the "
|
||||
f"opt-out. svstat:\n{_svstat(container_name)!r}"
|
||||
)
|
||||
# If status == "exited" instead, the gateway exited (also valid
|
||||
# pre-s6 semantics). The breadcrumb-absence check above is
|
||||
# already enough to confirm the redirect didn't fire.
|
||||
|
||||
|
||||
def test_gateway_run_no_supervise_env_var(
|
||||
built_image: str, container_name: str,
|
||||
) -> None:
|
||||
"""Env-var opt-out works identically to the CLI flag.
|
||||
|
||||
Useful when users can't easily change their `docker run` args
|
||||
(orchestration templates, K8s manifests) but can set env vars.
|
||||
"""
|
||||
subprocess.run(
|
||||
["docker", "run", "-d", "--name", container_name,
|
||||
"-e", "HERMES_GATEWAY_NO_SUPERVISE=1",
|
||||
built_image, "gateway", "run"],
|
||||
check=True, capture_output=True, timeout=30,
|
||||
)
|
||||
time.sleep(6)
|
||||
|
||||
logs = subprocess.run(
|
||||
["docker", "logs", container_name],
|
||||
capture_output=True, text=True, timeout=10,
|
||||
)
|
||||
combined = logs.stdout + logs.stderr
|
||||
assert "s6 supervision" not in combined, (
|
||||
f"env-var opt-out should have skipped the redirect; "
|
||||
f"breadcrumb in logs:\n{combined}"
|
||||
)
|
||||
|
||||
# Same as the CLI-flag test: the slot exists (reconciler creates
|
||||
# it) but should not have want-state up.
|
||||
inspect = subprocess.run(
|
||||
["docker", "inspect", "-f", "{{.State.Status}}", container_name],
|
||||
capture_output=True, text=True, timeout=10,
|
||||
)
|
||||
if inspect.stdout.strip() == "running":
|
||||
assert not _svstat_wants_up(container_name, "gateway-default"), (
|
||||
"HERMES_GATEWAY_NO_SUPERVISE=1: gateway-default has "
|
||||
"want-state up, implying the redirect dispatched `start` "
|
||||
f"despite the env-var opt-out. svstat:\n{_svstat(container_name)!r}"
|
||||
)
|
||||
|
||||
|
||||
def test_supervised_gateway_does_not_recurse(
|
||||
built_image: str, container_name: str,
|
||||
) -> None:
|
||||
"""The HERMES_S6_SUPERVISED_CHILD sentinel must prevent the
|
||||
supervised ``hermes gateway run`` from re-entering the redirect.
|
||||
|
||||
If recursion happened, every supervised gateway start would itself
|
||||
re-dispatch to s6 and exec ``sleep infinity`` — so the supervised
|
||||
gateway slot would never actually run a python ``hermes gateway
|
||||
run`` process. The slot would oscillate or settle into a state
|
||||
with no python in the supervise tree at all.
|
||||
|
||||
We verify by counting python processes whose argv contains
|
||||
``gateway run``: there should be at most one (the legitimately
|
||||
supervised gateway). Two or more would imply recursive spawning
|
||||
via the redirect → start → run → redirect → ... loop.
|
||||
"""
|
||||
subprocess.run(
|
||||
["docker", "run", "-d", "--name", container_name, built_image,
|
||||
"gateway", "run"],
|
||||
check=True, capture_output=True, timeout=30,
|
||||
)
|
||||
time.sleep(6)
|
||||
|
||||
# Count python processes running `hermes gateway run`. If the
|
||||
# recursion guard fails, s6 would respawn fresh `gateway run`
|
||||
# processes on every cycle, leaving multiple Python-process
|
||||
# descendants under the gateway-default supervise tree.
|
||||
r = _sh(container_name, "ps -eo pid,cmd | grep -v grep | grep -E 'python.*hermes.*gateway run' | wc -l")
|
||||
assert r.returncode == 0
|
||||
n = int(r.stdout.strip() or 0)
|
||||
assert n <= 1, (
|
||||
f"expected at most one supervised python `hermes gateway run` "
|
||||
f"process (the legitimately-supervised gateway); found {n}. "
|
||||
f"Recursion guard may have failed. "
|
||||
f"ps:\n{_sh(container_name, 'ps -eo pid,ppid,cmd').stdout}"
|
||||
)
|
||||
|
||||
# Stronger positive assertion: there should be exactly one
|
||||
# `sleep infinity` process whose parent is the main-wrapper.sh
|
||||
# CMD process (PID 17 typically). The static `main-hermes`
|
||||
# service has its own `sleep infinity` child; THAT one is fine
|
||||
# and unrelated to our redirect.
|
||||
r = _sh(
|
||||
container_name,
|
||||
# Find PID of the CMD process (main-wrapper.sh or its sh
|
||||
# parent), then count `sleep infinity` children.
|
||||
"ps -eo pid,ppid,cmd | grep -v grep | awk '/main-wrapper.sh|rc.init top/ { wrapper_pid=$1 } "
|
||||
"$3==\"sleep\" && $4==\"infinity\" && $2==wrapper_pid { c++ } END { print c+0 }'",
|
||||
)
|
||||
assert r.returncode == 0
|
||||
redirected = int(r.stdout.strip() or 0)
|
||||
assert redirected == 1, (
|
||||
f"expected exactly one `sleep infinity` parented to the CMD "
|
||||
f"wrapper (the redirect heartbeat); found {redirected}. "
|
||||
f"ps:\n{_sh(container_name, 'ps -eo pid,ppid,cmd').stdout}"
|
||||
)
|
||||
|
||||
|
||||
def test_dashboard_supervised_when_env_set(
|
||||
built_image: str, container_name: str,
|
||||
) -> None:
|
||||
"""When ``HERMES_DASHBOARD=1`` is set, ``docker run <image> gateway
|
||||
run`` should result in BOTH the gateway and the dashboard being
|
||||
supervised by s6 — the dashboard slot was always there but only
|
||||
activates with the env var. This is the headline benefit of the
|
||||
redirect: one container = supervised gateway + supervised
|
||||
dashboard, with zero extra user effort.
|
||||
"""
|
||||
subprocess.run(
|
||||
["docker", "run", "-d", "--name", container_name,
|
||||
"-e", "HERMES_DASHBOARD=1",
|
||||
built_image, "gateway", "run"],
|
||||
check=True, capture_output=True, timeout=30,
|
||||
)
|
||||
time.sleep(5)
|
||||
|
||||
# Both slots should report want-up.
|
||||
assert _svstat_wants_up(container_name, "gateway-default"), (
|
||||
f"gateway-default slot not up: {_svstat(container_name)!r}"
|
||||
)
|
||||
assert _svstat_wants_up(container_name, "dashboard"), (
|
||||
f"dashboard slot not up: {_svstat(container_name, 'dashboard')!r}"
|
||||
)
|
||||
|
||||
|
||||
def test_supervised_gateway_stdout_reaches_docker_logs(
|
||||
built_image: str, container_name: str,
|
||||
) -> None:
|
||||
"""The supervised gateway's stdout — including the rich-console
|
||||
startup banner — must reach ``docker logs``, not just the rotated
|
||||
log file under ``${HERMES_HOME}/logs/gateways/<profile>/current``.
|
||||
|
||||
Without the ``1`` action directive in ``_render_log_run``, s6-log
|
||||
swallows the gateway's stdout into the file and ``docker logs``
|
||||
only sees stderr (Python ``logging`` defaults to stderr). That's
|
||||
a poor user experience: the iconic "Hermes Gateway Starting…"
|
||||
banner with the ⚕ symbol is the most visible "yes, your gateway
|
||||
started" signal, and forcing users to ``docker exec`` + ``tail``
|
||||
the log file just to see it is friction users don't expect.
|
||||
|
||||
With the ``1`` directive, s6-log forwards every line to its own
|
||||
stdout (which propagates up through the s6-supervise pipeline to
|
||||
/init's stdout = container stdout = ``docker logs``) AND also
|
||||
writes a timestamped copy to the rotated file. Best of both.
|
||||
|
||||
We assert by looking for the literal banner glyph (``⚕``) — a
|
||||
distinctive character that won't appear in stderr-routed
|
||||
Python-logging output, so its presence in ``docker logs`` proves
|
||||
the stdout-tee is working.
|
||||
"""
|
||||
subprocess.run(
|
||||
["docker", "run", "-d", "--name", container_name, built_image,
|
||||
"gateway", "run"],
|
||||
check=True, capture_output=True, timeout=30,
|
||||
)
|
||||
# Banner is printed during gateway startup — give it time to
|
||||
# initialize past the imports + config-load phase.
|
||||
time.sleep(8)
|
||||
|
||||
logs = subprocess.run(
|
||||
["docker", "logs", container_name],
|
||||
capture_output=True, text=True, timeout=10,
|
||||
)
|
||||
combined = logs.stdout + logs.stderr
|
||||
|
||||
# The banner ⚕ symbol is the load-bearing assertion — it's unique
|
||||
# to gateway startup stdout output and won't appear in stderr
|
||||
# (Python logging) or s6 boot messages.
|
||||
assert "⚕" in combined or "Hermes Gateway Starting" in combined, (
|
||||
"Supervised gateway's stdout banner did not reach docker logs. "
|
||||
"This means the `1` action directive in _render_log_run isn't "
|
||||
"forwarding stdout to /init. "
|
||||
f"docker logs (last 2000 chars):\n{combined[-2000:]}\n"
|
||||
f"file contents:\n{_sh(container_name, 'cat /opt/data/logs/gateways/default/current').stdout}"
|
||||
)
|
||||
|
||||
# Cross-check: the same banner must also be in the rotated log
|
||||
# file (we kept the file destination, just added stdout). The
|
||||
# file version has s6-log's ISO 8601 timestamp prefix; the
|
||||
# docker logs version is raw.
|
||||
file_contents = _sh(
|
||||
container_name, "cat /opt/data/logs/gateways/default/current",
|
||||
).stdout
|
||||
assert "⚕" in file_contents or "Hermes Gateway Starting" in file_contents, (
|
||||
"Banner also missing from rotated log file — the file "
|
||||
"destination may have been dropped by the new s6-log script. "
|
||||
f"File contents:\n{file_contents}"
|
||||
)
|
||||
|
||||
Reference in New Issue